Output Ratings
•Voltage: 0 to 40 V
•Current (40°C then derate linearly 1%/°C from 40°C to 55°C): 0 to 128 A
Programming accuracy at (@ 25 ±5°C)
•Voltage 0.04% + 40 mV
•Current 0.1% + 65 mA
Ripple and Noise Constant Voltage Mode from 20 Hz
•rms: 1.0 mV
•Peak to peak: 10 mV
Readback Accuracy at 25°C ±5°C
•Voltage 0.05% + 60 mV
•Current 0.1% + 90 mA